Manual 3060 System
Version: September 2006
SimonsVoss Technologies AG Feringastraße 4 85774 Unterföhring Germany
Hotline 01805-SV3060 FAQs www.simons-voss.de
Telefon +49-89-99 228-0 Fax +49-89-99 228-222
If the contents of the foreign language version of the documentation differ from the contents of the original German version,
the original German version shall apply in case of doubt. We reserve the right to make technical changes.
Vista de pagina 0
1 2 3 4 5 6 ... 218 219

Indice de contenidos

Pagina 1 - Manual 3060 System

Manual 3060 System Version: September 2006 SimonsVoss Technologies AG • Feringastraße 4 • 85774 Unterföhring • Germany Hotline 01805-SV3060 • FA

Pagina 2 - Table of Contents

Digital Locking System 3060 Page 3 1.0 General Method of Operation The Digital Locking and Organization System 3060 is modularly constructed an

Pagina 3

PinCode Keypad 3068 Page 6 2.2 Operating modes The PinCode Keypad has four distinct operating modes: Mode: Explanation: Standby The PIN Code K

Pagina 4

PinCode Keypad 3068 Page 7 3.0 Start-up The first time the system is started up, you will need to replace the factory-set master PIN: 1 2

Pagina 5

PinCode Keypad 3068 Page 8 4.0 Programming PINs The Master PIN required for all programming procedures is defined by the user (e.g. the System

Pagina 6 - People to contact

PinCode Keypad 3068 Page 9 4.3 Procedure 5.0 Deleting PINs 5.1 Description To deactivate PINs again, follow these steps:

Pagina 7

PinCode Keypad 3068 Page 10 Attention: It is not possible to enter programming mode when there is a battery warning. This means that it is not p

Pagina 8

PinCode Keypad 3068 Page 11 6.2 Description To program the various transponders with the SimonsVoss software, please follow the procedure descri

Pagina 9

PinCode Keypad 3068 Page 12 6.3 Procedure 7.0 Reading out Transponders Anytime it is possible to read out the integrated tr

Pagina 10 - Digital Locking System 3060

PinCode Keypad 3068 Page 13 8.0 Resetting Transponders 8.1 Description To reset the various transponders, please proceed as follows: 1. Press

Pagina 11

PinCode Keypad 3068 Page 14 9.0 Opening In order to use the PinCode Keypad to open the associated locking, proceed as fol-lows: Enter a PIN that

Pagina 12

PinCode Keypad 3068 Page 15 11.0 Battery Warning To obtain a defined status for the PinCode Keypad and to minimise operating errors, a 2-level b

Pagina 13

Digital Locking System 3060 Page 4 2.2 Programming You will need the SmartCD and a PDA for programming the digital components. The data is encod

Pagina 14 - State of: September 2006

PinCode Keypad 3068 Page 16 When replacing the batteries, be absolutely sure that no water is allowed to penetrate into the housing and that the

Pagina 15

PinCode Keypad 3068 Page 17 13.0 Special Functions 13.1 Hidden Lock for SimonsVoss VdS Shuntlock 3066 The PinCode Keypad can be used for acti

Pagina 16 - 1.0 Method of Operation

PinCode Keypad 3068 Page 18 Important: Please set the two-time opening protocol (double-click) only when you are using a SimonsVoss VdS Shuntlock

Pagina 17 - 3.0 Additional Functions

LON – Network 3065 State of: September 2006

Pagina 18 - 4.0 Battery Warnings

LON – Network 3065 2 Content 1.0 Introduction _________________________________________4 1.1 General Information ____________________________

Pagina 19 - 5.0 Battery Replacement

LON – Network 3065 3 Content 7.0 Repeater ___________________________________________20 7.1 Method of Operation_________________________________

Pagina 20

LON – Network 3065 Page 4 1.0 Introduction In the following, we always speak of locking(s) and doors as the System 3060 components (locking cyli

Pagina 21 - 7.0 Potential Applications

LON – Network 3065 Page 5 1.1 General Information A so-called LockNode is placed next to the digital locking at a distance of about 30 cm (12 i

Pagina 22 - 8.0 Data Sheet

LON – Network 3065 Page 6 1.2 Connection to LPI-10 (Version: Open PCB With External Plug-in Power Supply) The LockNodes are connected to the Ce

Pagina 23 - Digital Half Cylinder 3061

LON – Network 3065 Page 7 2.0 The Software If you use a PC to administer the locking system, you only need the locking plan software LDB*1 or LS

Pagina 24

Digital Locking System 3060 Page 5 cylinder, Smart Relay or activation unit. 2.6 Network 3065 The cable-free Network 3065 is an online access

Pagina 25

LON – Network 3065 Page 8 3.0 Central Node 3.1 Method of Operation The CentralNode produces the interface between the PC and the network. One C

Pagina 26 - Digital Half Cylinder

LON – Network 3065 Page 9 4.0 Lock Node 4.1 Method of Operation 4.2 Assembly Instructions The LockNodes are pre-configured by Simons

Pagina 27

LON – Network 3065 Page 10 In order to guarantee proper radio transmission, you should maintain the following distances between the LockNode and

Pagina 28

LON – Network 3065 Page 11 Connect the network cable to terminals 1 and 2 of the LockNode. If you need an antenna extender because of a double d

Pagina 29

LON – Network 3065 Page 12 4.4 LockNode Inputs and Outputs Terminals 3 to 8 are available for floating inputs or one output. The inputs transmi

Pagina 30

LON – Network 3065 Page 13 5.0 LPI-10 5.1 General Warnings The LPI-10 is a regulated power supply, designed for use in single-phase AC power ne

Pagina 31

LON – Network 3065 Page 14 5.2.2 Assembly Instructions The LPI-10 is intended for installation in distribution boxes with DIN rails. You will al

Pagina 32

LON – Network 3065 Page 15 5.3 LPI-10 Compact (Version: compact construction with 230V power supply from the customer) 5.3.1 Installation Only

Pagina 33

LON – Network 3065 Page 16 5.3.2 Method of Operation You need at least one LPI-10 for each network segment in order to supply the Lock-Nodes. T

Pagina 34

LON – Network 3065 Page 17 Build the LPI-10 into the separate segments in such a way that there is voltage of at least 35V DC at each LockNode. C

Pagina 35

Digital Locking System 3060 Page 6 After the access list has been read out with the programming device or network nodes, it is imported into the

Pagina 36

LON – Network 3065 Page 18  Routers need a 230 V AC power supply from the customer (outlet).  Routers, as they come from the factory, do no

Pagina 37

LON – Network 3065 Page 19 6.3 Installation Example

Pagina 38 - Content

LON – Network 3065 Page 20 7.0 Repeater 7.1 Method of Operation The repeater increases the allowable communication distance by regenerating the

Pagina 39 - 2.0 Product Description

LON – Network 3065 Page 21 9.0 Network Cable 9.1 General Information Every LockNode is networked with one line consisting of two twisted wires

Pagina 40 - 3.0 Before Ordering

LON – Network 3065 Page 22 Bezeichnung Präsentation 2Bus System Bus System CablingCabling((ValuesValuesforforCat5 Cat5 CableCable))LPI 10LPI 10LP

Pagina 41 - 4.0 Before Installation

LON – Network 3065 Page 23 Bezeichnung Präsentation 3Cabling With no Topology (Values for Cat5 Cable)Cabling With no Topology (Values for Cat5 Ca

Pagina 42 - POSITIVE POLE UP

LON – Network 3065 Page 24 10.0 Planning Examples 10.1 Connecting External Buildings via Twisted Pair, Modem & TCP/IP Remark: The planning

Pagina 43 - 5.0 Installation

LON – Network 3065 Page 25 10.2 Network via Modem Bezeichnung Präsentation 5Network via ModemNetwork via ModemServerServerwith LDBwith LDBLNLNL

Pagina 44 - 6.0 Connection Assignments

LON – Network 3065 Page 26 11.0 Security Because the Network 3065 records and logs critical data, it must be reliably protected from unauthorise

Pagina 45

LON – Network 3065 Page 27 12.0 Answers to the Most Common Questions Regarding the Network - Is it possible to use a cable that is already the

Pagina 46

Digital Locking Cylinder 3061 VdSState of: September 2006

Pagina 47

LON – Network 3065 Page 28 - What is an LPI-10 Compact? An LPI-10 Compact essentially corresponds to the LPI-10, but with the difference that

Pagina 48

LON – Network 3065 Page 29 13.0 Data sheet CentralNode Dimensions 100 x 54 x 30 mm [L/W/H] Network connecting cable 200 cm (approx. 6.6 fee

Pagina 49 - SREL.AV

LON – Network 3065 Page 30 LPI-10 (Version: Compact) Input quantities Nominal input voltage UE AC 120 / 230V Input voltage ran

Pagina 50

LON – Network 3065 Page 31 Protection class to VDE 0106 Part 1 I (with ground terminal) Electrical isolation, primary/secondary SELV to EN 609

Pagina 51 - Externe Antenne

WaveNet Radio Network 3065 Version: September 2006

Pagina 52

WaveNet Radio Network 3065 Page 2 1.0 Introduction _________________________________________3 2.0 Transmission media_________________________

Pagina 53 - 8.0 Serial Interface

WaveNet Radio Network 3065 Page 3 1.0 Introduction In the following, the components of the System 3060 (locking cylinders, Smart Relays, block

Pagina 54 - 9.0 Maintenance

WaveNet Radio Network 3065 Page 4 To summarise, networking enables the entire access control system to be configured and monitored from one cen

Pagina 55

WaveNet Radio Network 3065 Page 5 In the year 2000, a special SRD (short range device) band in the 868 MHz range was made available for this typ

Pagina 56 - 10.0 Data sheet

WaveNet Radio Network 3065 Page 6 4.0 What are the factors to look out for? Regardless of the method, radio transmission is subject to a rang

Pagina 57 - Smart Output Module

Digital Locking Cylinder 3061 VdS Page 2 1.0 Method of Operation __________________________________3 1.1 General Information _________________

Pagina 58

WaveNet Radio Network 3065 Page 7 5.0 Secure message transmission The transmission security of a message by radio in the WaveNet depends upon:

Pagina 59

WaveNet Radio Network 3065 Page 8 6.1 Computers Using special communication node software (CommNode), computers can be integrated into WaveNet:

Pagina 60

WaveNet Radio Network 3065 Page 9 segment. The WaveNet Router Node blocks out all other data from the downstream segment. WaveNet Router Nodes

Pagina 61

WaveNet Radio Network 3065 Page 10 WaveNet Repeater Nodes are used in situations such as the following: • If the radio range to a Lock Node is

Pagina 62

WaveNet Radio Network 3065 Page 11 Backbone wiring: An RS485 segment (backbone) is wired using a bus comprising a shielded, standard KAT5 cable

Pagina 63 - 6.0 Connections

WaveNet Radio Network 3065 Page 12 Inside the system, a WaveNet Lock Node can only be allocated to one digital lock (locking cylinder, Smart Rel

Pagina 64

WaveNet Radio Network 3065 Page 13 In order to make installation as easy as possible, the casing of the WaveNet Lock Node is designed to fit int

Pagina 65

WaveNet Radio Network 3065 Page 14 The output is used to send signals to external systems such as sensors, heaters, lights and so on. The output

Pagina 66

WaveNet Radio Network 3065 Page 15 7.0 Network structure In the network structure depicted above, different users with different rights can a

Pagina 67

WaveNet Radio Network 3065 Page 16 number of CommNodes can be connected via the Intranet or Internet. This enables what is known as ‘branch oper

Pagina 68

Digital Locking Cylinder 3061 VdS Page 3 Drilling protection 1.0 Method of Operation 1.1 General Information The Digital Locking Cylinder 3061

Pagina 69

WaveNet Radio Network 3065 Page 17 RS232 Cable Segment 1 LN LN LN LN LN LN LN LN Radio 868 MHz Segment 3 Radio 868 MHz Segment 4 Radio868 MHz

Pagina 70

WaveNet Radio Network 3065 Page 18 8.0 Security Since WaveNet gathers and records critical data, it has to be reliably protected against unauth

Pagina 71

WaveNet Radio Network 3065 Page 19 9.0 Battery warning If the voltage of the battery used to supply the Lock Node drops below a certain level,

Pagina 72

WaveNet Radio Network 3065 Page 20 Der WaveNet LockNode sollte in Höhe des Schließzylinders angebracht werden. (Einbau vorzugsweise in Standard

Pagina 73 - Transponder 3064

WaveNet Radio Network 3065 Page 21 11.0 Technical specifications 11.1 WaveNet power supply Order number WN.POWER.SUPPLY.PPP Description Exte

Pagina 74

WaveNet Radio Network 3065 Page 22 11.4 WaveNet Central Node with 868 MHz radio module Order number WN.CN.SR Description WaveNet Centr

Pagina 75

WaveNet Radio Network 3065 Page 23 11.6 WaveNet Router Node as 868 MHz Repeater Order number WN.RN.R Description WaveNet Router Node as

Pagina 76

WaveNet Radio Network 3065 Page 24 11.8 WaveNet Lock Node Order number WN.LN Description Battery-powered WaveNet Lock Node (node for netw

Pagina 77

WaveNet Radio Network 3065 Page 25 Order number WN.LN.O.I/O Description WaveNet Lock Node with integrated battery, without inputs and output

Pagina 78

Shunt lock function 3066 Operator Instructions Version: January 2004

Pagina 79

Digital Locking Cylinder 3061 VdS Page 4 2.0 Special Models The standard Digital Locking Cylinder 3061 VdS is equipped as a TZC version, which m

Pagina 80

VdS Shunt lock function 3066 Content Alarm SystemActivation unit with configuration MASTERDeactivation unit Deactivation unit Deactivation unit

Pagina 81

VdS Shunt lock function 3066 Page 3 1.0 Shunt lock function 3066 System Components In objects protected by the alarm, measures must be taken to

Pagina 82 - Q3007 Biometric Transponder

VdS Shunt lock function 3066 Page 4 2.0 Shunt lock function 3066 Operation Switching on the alarm system (burglar alarm system, BAS) The perso

Pagina 83

VdS Shunt lock function 3066 Page 5 • Special model If you want to keep a log of who switched the alarm system and when, you need an activation

Pagina 84

VdS Shunt lock function 3066 Page 6 3.0 Special Versions of the Shunt lock function 3066 3.1 Operating the Activation Unit without a Deactivat

Pagina 85

VdS Shunt lock function 3066 Page 7 Data Sheet MA, SA and DA Operating voltage 8 to 16 Volts DC Current consumption < 30 mA A

Pagina 86 - Delete state: LED flashes red

VdS Shunt lock function 3066 Version: September 2006

Pagina 87

VdS Shunt lock function 3066 Content Alarm SystemActivation unit with configuration MASTERDeactivation unit Deactivation unit Deactivation unit

Pagina 88

VdS Shunt lock function 3066 Content 2.4 Installing the Slave Activation Unit (SA) ____________________ 14 2.4.1 Testing the Slave Activation U

Pagina 89

VdS Shunt lock function 3066 Page 4 1.0 Functional Description 1.1 General Information In objects protected by the alarm, measures must be take

Pagina 90

Digital Locking Cylinder 3061 VdS Page 5 3.3 Logging Unauthorised Access Attempts For cylinder version 10.2 and later and in combination with t

Pagina 91

VdS Shunt lock function 3066 Page 5 Switching on the alarm system (burglar alarm system, BAS) The person with switching authorization presses hi

Pagina 92

VdS Shunt lock function 3066 Page 6 Time zone control und access logging The activation units (master and slaves) can log activation/deactivati

Pagina 93

VdS Shunt lock function 3066 Page 7 2.0 Assembly Instructions 2.1 General Information on Installing the Components Always install in the prote

Pagina 94

VdS Shunt lock function 3066 Page 8 + 8...16V Masse +LED - LED C NC N0 SAB0 SAB

Pagina 95

VdS Shunt lock function 3066 Page 9 2.2.1 Testing the Deactivation Unit (DA): To test, connect the deactivation unit to a 9-volt compound batte

Pagina 96

VdS Shunt lock function 3066 Page 10 Test the shunt lock function again after you have connected the lock switch contact. Try to deactivate the l

Pagina 97

VdS Shunt lock function 3066 Page 11 + 8..16 V Masse +LED - LED C NC N0 SAB0 SA

Pagina 98

VdS Shunt lock function 3066 Page 12 The BAC must draw pin 29 to ground for the acoustic acknowledgement. Jumper B2 is inserted: ⇒ Ma

Pagina 99

VdS Shunt lock function 3066 Page 13 • External light emitting diode You can connect an external light emitting diode to soldering terminals 3

Pagina 100 - PinCode Keypad 3068

VdS Shunt lock function 3066 Page 14 + 8..16 V Masse +LED - LED C NC N0 SAB0 SA

Pagina 101

Digital Locking Cylinder 3061 VdS Page 6 4.2 Transponder If the transponder battery voltage is coming to an end, eight short signal tones, comin

Pagina 102

VdS Shunt lock function 3066 Page 15 Jumper B2 is inserted: ⇒ Maximum transmitting range. For VdS-compliant installation, however, you must then

Pagina 103

VdS Shunt lock function 3066 Page 16 • Switch contacts Soldering terminal 5 to 7 are not needed for the slave activation unit unless you want to

Pagina 104

VdS Shunt lock function 3066 Page 17 DA MA SA Deactivation request Solder pin 13 Solder pin 14 - Deactivation acknowledgement Solder pin 14

Pagina 105

VdS Shunt lock function 3066 Page 18 7. Instead of operating the transponder at the MA, the slave activation units (after transponder activation

Pagina 106

VdS Shunt lock function 3066 Page 19 After you have completed the installation work, carry out a function test. Do this by operating an authoriz

Pagina 107

VdS Shunt lock function 3066 Page 20 3.0 Programming 3.1 Programming the Activation Units (MA and SA) If you want to add the shunt lock compon

Pagina 108

VdS Shunt lock function 3066 Page 21 In the locking plan, make a cross by the employees who are authorized to turn the alarm system on and off.

Pagina 109

VdS Shunt lock function 3066 Page 22 3.2 Programming the Deactivation Units (DA) Click the line in the locking plan above the one where you wan

Pagina 110

VdS Shunt lock function 3066 Page 23 Read out the shunt lock components: Programming  Read unknown locking. The type of the component (deactivat

Pagina 111

VdS Shunt lock function 3066 Page 24 4.0 Installation 4.1 Installing the Deactivation Unit Install the deactivation unit DA in the immediate v

Pagina 112

Table of Contents Version: June 2006

Pagina 113 - LON – Network 3065

Digital Locking Cylinder 3061 VdS Page 7 Fix the lock nut in position with the special tool and press it against the flange. Now turn the inner k

Pagina 114

VdS Shunt lock function 3066 Page 25 4.2 Installing the Activation Unit (MA and SA) You should install the activation unit (AU), no matter whe

Pagina 115

VdS Shunt lock function 3066 Page 26 4.3 VdS-Compliant Installation of the Activation Unit (MA and SA) VdS-compliant installation must guarant

Pagina 116

VdS Shunt lock function 3066 Page 27 7. You can also optionally use an activation unit without antenna extender. Install it as described in Chap

Pagina 117

VdS Shunt lock function 3066 Page 28 5.0 Special Versions of the Shunt lock function 3066 5.1 Operating the Activation Unit without a Deactiva

Pagina 118

VdS Shunt lock function 3066 Page 29 6.0 Data Sheet MA, SA and DA Operating voltage 8 to 16 volts DC Current consumption < 30 mA

Pagina 119

Programming Transponder 3067 State of: June 2006

Pagina 120

Programming Transponder 3067 Content 1.0 Introduction _________________________________________3 2.0 Backup Card __________

Pagina 121

Programming Transponder 3067 Page 3 1.0 Introduction The Programming Transponder 3067 is used for programming Digital Locking Cylinder 3061 and

Pagina 122

Programming Transponder 3067 Page 4 3.0 Programming Notes Always position only one locking cylinder in the immediate vicinity of the Programming

Pagina 123

Programming Transponder 3067 Page 5 its button one time. Attention: you must press the button during the LED’s blinking phase. The data is then t

Pagina 124

Digital Locking Cylinder 3061 VdS Page 8 6.4 Inserting the Digital Cylinder Into the Lock First turn the lock pin until it is pointing straight

Pagina 125

Programming Transponder 3067 Page 6 3.5 Emergency Opening It is possible to perform an emergency opening with the Programming Transponder. Proce

Pagina 126

Programming Transponder 3067 Page 7 4. The Programming Transponder repeats the ID number that you enter as a check. First the LED briefly lights

Pagina 127

PalmCD2 Programming Device State of : September 2004

Pagina 128

PalmCD2 Programming Device Content 1.0 Introduction _________________________________________3 2.0 Commissioning _____

Pagina 129

PalmCD2 Programming Device Page 3 1.0 Introduction The PalmCD2 is a programming device that was developed especially for operation on a PC/Lapto

Pagina 130

PalmCD2 Programming Device Page 4 been tested and approved by SimonsVoss). In this configuration, you can program all digital components directly

Pagina 131

Caption State of: June 2006

Pagina 132

Caption Page 2 Explanation of technical terms Access logging Additional function of the digital components in the TC version: The digital lockin

Pagina 133

Caption Page 3 SmartCD The SmartCD is a programming device that was developed especially for wireless operation with a PDA. It makes it very ea

Pagina 134

Caption Page 4 Special symbols used in the text ☺ Remark, tip  Example  Attention Subject to technical modifications.

Pagina 135

Digital Locking Cylinder 3061 VdS Page 9 8.0 Data Sheet Knobs Material Stainless steel Colours Brushed stainless steel Brass Diameter 30

Pagina 136

Digital Half Cylinder 3061 State of: September 2006

Pagina 137

Digital Half Cylinder 3061 Content 1.0 Method of Operation __________________________________4 1.1 General Information ______

Pagina 138

Digital Half Cylinder 3061 Content 6.0 Installation Instructions________________________________8 6.1 General Information ____________________

Pagina 139

Digital Half Cylinder Page 4 1.0 Method of Operation 1.0 General Information The outer dimensions of the Digital Half Cylinder exactly match th

Pagina 140

Digital Half Cylinder Page 5 3.0 Additional Functions 3.1 OMRON All product versions can be operated in OMRON mode. You will find a detailed d

Pagina 141

Digital Half Cylinder Page 6 4.0 Battery Warnings 4.1 Half Cylinder Warning level 1 for main battery If the main battery of the half cylinder

Pagina 142

Digital Half Cylinder Page 7 5.0 Battery Replacement Only authorised personnel are permitted to replace the battery. Use only batteries that ar

Pagina 143

Table of Contents Seite 2 P People to Contact Sales Technical Address in Munich D Digital Locking System 3060 General method of operatio

Pagina 144 - WaveNet Radio Network 3065

Digital Half Cylinder Page 8 6.0 Installation Instructions 6.1 General Information Only trained and authorised personnel are permitted to perf

Pagina 145 - All rights reserved

Digital Half Cylinder Page 9 pipe locknutpipe setscrews knob main batterybackuo battery electronics moduleallen screw flangecable slot6.4 Insta

Pagina 146

Digital Half Cylinder Page 10 6.4.2 Installing the Knob and Flange of the Half Cylinder 1. Put on the locknut. The flat surface with the bore

Pagina 147

Digital Half Cylinder Page 11 6.5 Installation Behind Blanks for Half Cylinders With 2 Setscrews (Old Flange Mounting) 6.5.1 Rem

Pagina 148

Digital Half Cylinder Page 12 the flange holds securely. To find the exact position quickly, the flat surfaces of the pipe and flange have black

Pagina 149

Digital Half Cylinder Page 13 7.0 Data Sheet Dimensions Standard length Standard length Multirast (MR) 30/10 mm 30/15 mm Max. profile len

Pagina 150

Smart Relay: SREL, SREL.ZK, SREL.AKVState of: September 2006

Pagina 151

Smart Relay: SREL, SREL.ZK, SREL.ADV Content 1.0 Important Information _________________________________4 2.0 Product Description _________

Pagina 152

Smart Relay: SREL, SREL.ZK, SREL.ADV Content 7.11 Number of expansion modules ____________________________ 15 7.12 Pulse length _______________

Pagina 153

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 4 1.0 Important Information Safety remark: Caution! – Incorrect handling of the batteries and storage

Pagina 154

Table of Contents Seite 3 Q Biometric Transponder Q 3007 Method of operation Learn state Recognize state Delete state PinCode Keypad 306

Pagina 155

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 5 3.0 Before Ordering 3.1 Determine Which Version of the Smart Relay you need 1. Smart Relay basic

Pagina 156

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 6 3.4 Determine the Installation Position The range from the transponder to the Smart Relay (reader r

Pagina 157

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 7 4.1 Installation of the Backup battery Backup Batterie nur einsetzen, wenn das Smart Relais mitNetz

Pagina 158

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 8 5.0 Installation  Switch off the supply voltage (if necessary, pull out the plug or disconnect the

Pagina 159

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 9 + / ~- / ~NCCOMNOBatterie SREL.BATNetzteil{Relais{Antenna Power BatteryRe-6.0 Connection Assignmen

Pagina 160 - Segment 1

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 10 6.2 SREL.ADV 6.3 Description of the SREL, SREL.ZK and SREL.ADV Connection Name Symbol Description

Pagina 161

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 11 7.0 Programming and Configuration When you choose Smart Relay as the locking type in the SimonsVos

Pagina 162

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 12 7.1 Access control Only possible for SREL.ZK and SREL.ADV The last 1024 transponder activation’s ar

Pagina 163

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 13 1. Manual locking: The door is not locked automatically according to the selected time of day, but

Pagina 164

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 14 + / ~- / ~NCCOMNOBrownWhiteGreenGreyYellowBatterie SREL.BATNetzteil{Relais{}Externe AntenneSREL.AV1

Pagina 165

Table of Contents Seite 4 K Key Explanation of technical terms Special Symbols

Pagina 166

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 15 7.8 No acoustic programmer acknowledge Only SREL.ADV Mark this field if you want no programmer ack

Pagina 167

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 16 + / ~- / ~NCCOMNOBrownWhiteGreenGreyYellowBatterie SREL.BATNetzteil{Relais{}Externe AntenneSREL.AVV+

Pagina 168

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 17 + / ~- / ~NCCOMNOBrownWhiteGreenGreyYellowBatterie SREL.BATNetzteil{Relais{}Externe AntenneSREL.AVF3

Pagina 169 - Shunt lock function 3066

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 18 + / ~- / ~NCCOMNOBrownWhiteGreenGreyYellowBatterie SREL.BATNetzteil{Relais{}Externe AntenneSREL.AV1

Pagina 170 - VdS Shunt lock function 3066

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 19 + / ~- / ~NCCOMNOBrownWhiteGreenGreyYellowBatterie SREL.BATNetzteil{Relais{}Externe AntenneSREL.AV1

Pagina 171

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 20 9.2 Backup Battery A discharged backup battery can cause the internal clock in the type SREL.ZK or

Pagina 172

Smart Relay: SREL, SREL.ZK, SREL.ADV Page 21 10.0 Data sheet Housing made of black plastic: Dimensions [LxWxH] 72 x 57 x 25.5 mm (approximately

Pagina 173

Smart Output Module State of: June 2006

Pagina 174

Smart Output Module Content 1.0 Important Information _________________________________4 2.0 Product Description _____________________________

Pagina 175

Smart Output Module Content 9.0 Meaning of the LEDs _________________________________15 9.1 LEDs for Each Output _____________________________

Pagina 176

People to contact Version: September 2006

Pagina 177

Smart Output Module Page 4 1.0 Important Information  Installation of a SimonsVoss Smart Output Module requires knowledge in the areas of appr

Pagina 178

Smart Output Module Page 5 3.0 Before Ordering 3.1 Smart Relay At least one type SREL.ADV Smart Relay is necessary for operating a Smart Output

Pagina 179

Smart Output Module Page 6 4.0 Before Installation  Unpack the Smart Output Module and inspect it for external damages.  Connect the Smart O

Pagina 180

Smart Output Module Page 7 Output-wenn die Versorgungsspannung unter10,5 V +/-0,5V absinkt schaltet dieserAusgang aus.I- / I+ Nicht belegtBusansc

Pagina 181

Smart Output Module Page 8 6.2 Connection Assignments Name Symbol Description Output Out If the supply voltage falls below 10.0 VDC +/- 0.5V,

Pagina 182

Smart Output Module Page 9 7.0 Connection to the Smart Relay +/~-/~CAB+VF3F2F1BNWHGNGYYLNetzteil+-|A-|K1|A+| +|K2|8a|8b|7a|7b|6a|6b|5a|5bI-|I

Pagina 183

Smart Output Module Page 10 7.1 Standard Power Supply Connection 7.2 Emergency Release Connection for a Fire Alarm System When the fire alar

Pagina 184

Smart Output Module Page 11 7.3 Protective Circuit to Prevent an Opening when the Supply Voltage Fails When the supply voltage range falls belo

Pagina 185

Smart Output Module Page 12 7.4 Protective Circuit for the Signaling Option Outputs Each pair of terminals opposite one another (1 and 5, 2 and

Pagina 186

Smart Output Module Page 13 8.0 Programming and Configuration 8.1 General Information To program the Smart Output Module, connect it to a type

Pagina 187

People to contact Page 2 SALES If you have any questions please contact our specialist dealers, or the sales representative responsible for your

Pagina 188

Smart Output Module Page 14 8.4 Adjust the Pulse Length The modules appear in the locking plan as the locking type "expansion module"

Pagina 189

Smart Output Module Page 15 9.0 Meaning of the LEDs 9.1 LEDs for Each Output Each of the 8 outputs has an LED assigned to it. This LED displa

Pagina 190

Smart Output Module Page 16 10.0 Technical Specifications Housing made of plastic with transparent cover for mounting on DIN rail. Dimensions:

Pagina 191 - DA DA DA

Transponder 3064 State of: September 2006

Pagina 192

Transponder 3064 Content 1.0 Method of Operation __________________________________3 1.1 General ____________________________________

Pagina 193

Transponder 3064 Page 3 1.0 Method of Operation 1.1 General The Transponder 3064 is a digital “key” that is programmed with the locking plan so

Pagina 194

Transponder 3064 Page 4 1.2 Higher Priority Locking Level If it is necessary to have transponders that are authorised for more than 3 mutually

Pagina 195

Transponder 3064 Page 5 2.0 Special Models 2.1 Password Transponder Instead of manually entering the locking system password, you can transmit

Pagina 196

Transponder 3064 Page 6 Explosion Protection Transponder 2.7 General Information This special product is a transponder that is permitted to be

Pagina 197

Transponder 3064 Page 7 3.0 Additional Functions The following functions can be activated in the locking plan software: 3.1 Time Zone Control

Pagina 198

Digital Locking System 3060 State of: June 2006

Pagina 199

Transponder 3064 Page 8 4.0 Battery Replacement 4.1 Battery Replacement 3064 If a battery warning occurs, then the transponder battery can be

Pagina 200

Transponder 3064 Page 9 6.0 Data Sheet Housing • Made of weather-resistant plastic • Colour: Black • Degree of protection: IP 65 • Diame

Pagina 201

Q3007 Biometric Transponder State of: September 2006

Pagina 202 - DA DA DA

Q3007 Biometric Transponder Content 1.0 General Instructions __________________________________3 1.1 Safety instructions ____________________

Pagina 203

Q3007 Biometric Transponder Page 3 1.0 General Instructions Please take 15 minutes to familiarise yourself with how your Biometric Transponder

Pagina 204

Q3007 Biometric Transponder Page 4 2.0 Overview of function 2.1 Basic information on operation The Biometric Transponder Q3007 scans fingerp

Pagina 205 - Programming Transponder 3067

Q3007 Biometric Transponder Page 5 2.3 How the transponder works You can interrupt the action in each mode by pressing the button briefly to c

Pagina 206

Q3007 Biometric Transponder Page 6 Please note: The first two fingerprints to be scanned in are automatically (!) the Administrator fingerprints

Pagina 207

Q3007 Biometric Transponder Page 7 Further fingerprints (maximum 4) can be scanned in as the Administrator fingerprints have been, except that t

Pagina 208

Q3007 Biometric Transponder Page 8 6. Now repeat step 4 twice again (so that you have drawn your finger three times across the fingerprint sens

Pagina 209

Digital Locking System 3060 Register 1.0 General Method of Operation ___________________________3 2.0 The Components of

Pagina 210

Q3007 Biometric Transponder Page 9 2.6 "Recognise" mode: one-off triggering of transponder The mode known as the Recognise mode is t

Pagina 211

Q3007 Biometric Transponder Page 10 3.0 "Delete" mode: deleting fingerprints Both individually scanned fingerprints and all the fin

Pagina 212 - PalmCD2 Programming Device

Q3007 Biometric Transponder Page 11 To enter Transparent mode, please proceed as follows: 1. Press and hold the transponder button (longer tha

Pagina 213

Q3007 Biometric Transponder Page 12 7.0 Technical Data Dimensions: H x W x D 65 x 32 x18 mm Weight 22 g Colour Grey, with blue button Opera

Pagina 214

Q3007 Biometric Transponder Page 13 8.0 Table of Diode Signals LED Mode off Standby off moving finger on sensor followed by comparison with s

Pagina 215

PinCode Keypad 3068 State of : September 2006

Pagina 216 - Caption

PinCode Keypad 3068 Content 1.0 General information 4 1.1 Safety Remarks __________________________________________ 4 1.2 Product Description __

Pagina 217

PinCode Keypad 3068 Content 13.0 Special Functions 17 13.1 Hidden Lock for SimonsVoss VdS Shuntlock 3066 ______________ 17 13.2 Miscellaneous _

Pagina 218

PinCode Keypad 3068 Page 4 1.0. General information Please take 15 minutes and read through these Instructions in order to familiarise yoursel

Pagina 219

PinCode Keypad 3068 Page 5 1.2 Product Description The PinCode Keypad 3068 is a digital "key" (transponder), which opens SimonsVoss lo