TASKS
Receiving commands from the GUI or CommNode Server and forwarding
them to the SimonsVoss hardware components. Upon completion, the result
of the action is sent back to the originator.
Receiving, processing and forwarding events.
CONFIGURATION
PROCEDURE
 Network
 Communication nodes
New
Enter “name”
Enter “computer name”
Apply
Search port
Create and save Config. files
Select path where the configuration files are to be saved
Copy the files appcfg.xml, msgcfg.xml und netcfg.xml to the directory
[SYSTEM]:\Programme\SimonsVoss\CommNode
NOTE
The files can also be created on any computer with GUI and can then be
saved via the network.
Each time the configuration of a CommNode is changed, the config. files must
be recreated and copied or transferred to the CommNode directory.
The service must be stopped and restarted manually if major changes occur,
such as changing the name of the computer.
The user who started the “SimonsVoss CommNode” service must either be a
member of the administrator group or have the special right to stop and start
the service.